2U 19″ rack mount power monitoring distribution unit. 32 Amp C-Form input breaking out to two banks of powerCON TRUE1 outputs, each protected at 16 Amps. Built for audio visual, theatre, multimedia and touring rack applications where locking TRUE1 outputs and per-circuit monitoring are needed.
The PDU32-CTR1 takes a 32A C-Form single-phase input and splits it across two independent 16A circuits, each feeding four Neutrik powerCON TRUE1 (NAC3FPX-TOP) locking outputs. Each circuit has its own 16A thermal breaker and power monitoring, with colour-coded channels for fast identification in a busy rack.
Input: 32 Amp 240V C-Form single-phase blue connector, IP44
Channel / Circuit A Output: Combined load of 16 Amps across 4 x powerCON TRUE1, NAC3FPX-TOP, on 16 Amp overload protection.
Channel / Circuit B Output: Combined load of 16 Amps across 4 x powerCON TRUE1, NAC3FPX-TOP, on 16 Amp overload protection.
Also Includes:
– LCD power monitor displaying current, voltage, power and energy levels.
– Two separate 16 Amp thermal breaker switches, one per bank of 4 outputs.
– Earthing link, 4mm screw terminal for grounding purposes.
– Colour coded channels, A (grey) & B (yellow) for easy identification.
Technical Information
| Data Sheet | Data Sheet and User Guide |
|---|---|
| Number of Sockets | 8 x powerCON TRUE1 |
| Plug Type | powerCON TRUE1 (NAC3FPX-TOP) |
| Input | 32A C-Form IP44 |
| Size (U) | 2U |
| Weight | 2.69kg |
| Finish | Black |